Details for sauna 2
Checklist
Check door adjustment and torque hinge bolts to the recommended 7.5nm, Check and tighten door handle, replace buttons if required., Check and tighten door catch, Check tablet door hinges, tighten if necessary, Check the door seal and note if replacement required, Check tablet door magnetic catch, Check USB charging port is working, Remove full spectrum heaters and clean the heaters and the glass. Replace heaters., Test the chromatherapy remote and replace batteries if required, Clean the glass windows and roof both inside and outside, Check for loose slats on the bench and heater guards. Use brad nailer to secure if loose., Check all lights and replace if required, Note the heater temperatures below
Heater Measurements
Sauna Temp:2
Left Panel: 68
Left Bottom Panel:66
Left FS Heater:177
Right Panel: 68
Right Bottom Panel:66
Right FS Heater:177
Other notes
Comments:
USB charger not working,replaced charger but seems no power coming from the power supply to charger unit.Will log with Clearlight and return to fix.
Adjusted door
Fastened back top slat with screws
Floor cracks noted,worse than room 3 about 1mm approx.Will keep monitoring
Attachments: https://bizinstall.com.au/wp-content/uploads/formidable/10/16558514244958714968825318517347-150×150.jpg, https://bizinstall.com.au/wp-content/uploads/formidable/10/16558519820663864550491255896558-150×150.jpg, https://bizinstall.com.au/wp-content/uploads/formidable/10/16558520000643118121651955495294-150×150.jpg, https://bizinstall.com.au/wp-content/uploads/formidable/10/16558520079563580841664487827050-150×150.jpg, https://bizinstall.com.au/wp-content/uploads/formidable/10/16558520156635167884541222262730-150×150.jpg