Details for sauna 3

Checklist

Check door adjustment and torque hinge bolts to the recommended 7.5nm, Check felt strips on the side glass panels is not protruding, Check and tighten door handle, replace buttons if required., Check and tighten door catch, Check tablet door hinges, tighten if necessary, Check the door seal and note if replacement required, Check tablet door magnetic catch, Check USB charging port is working, Remove full spectrum heaters and clean the heaters and the glass. Replace heaters., Test the chromatherapy remote and replace batteries if required, Clean the glass windows and roof both inside and outside, Check for loose slats on the bench and heater guards. Use brad nailer to secure if loose., Check all lights and replace if required, Check and clean thermal sensor of dust

Heater Measurements 

Sauna Temp:3

Left Panel: 65

Left Bottom Panel:54

Left FS Heater:171

Right  Panel: 65

Right Bottom Panel:54

Right FS Heater:171

Other notes

Comments:

1.Back heater panel was loose, had to move slightly left to allow screws to grab in the timber.
2.Laminate floor is badly burnt, suggest report to Clearlight under warranty for floor inserts replacement.
3 Report chromatography units under warranty for replacement.
4.Fix loose slat

Attachments: https://bizinstall.com.au/wp-content/uploads/formidable/10/17665219243834926762665146082327-150×150.jpg, https://bizinstall.com.au/wp-content/uploads/formidable/10/17665219467132190538075736031223-150×150.jpg, https://bizinstall.com.au/wp-content/uploads/formidable/10/17665229088455831701332149659182-150×150.jpg