Details for sauna 2
Checklist
Check door adjustment and torque hinge bolts to the recommended 7.5nm, Check felt strips on the side glass panels is not protruding, Check and tighten door handle, replace buttons if required., Check and tighten door catch, Check tablet door hinges, tighten if necessary, Check the door seal and note if replacement required, Check tablet door magnetic catch, Check USB charging port is working, Remove full spectrum heaters and clean the heaters and the glass. Replace heaters., Test the chromatherapy remote and replace batteries if required, Clean the glass windows and roof both inside and outside, Check for loose slats on the bench and heater guards. Use brad nailer to secure if loose., Check all lights and replace if required
Heater Measurements
Sauna Temp:2
Left Panel: 77
Left Bottom Panel:70
Left FS Heater:166
Right Panel: 77
Right Bottom Panel:70
Right FS Heater:166
Other notes
Comments:
Replaced faulty downlight
Adjusted door to fit flush with left panel,see pic before and after
Door hinge gaskets are compressed to the max.Will require gaskets replaced as soon as possible
Replaced door seal
FS heaters were very clogged with dust,all good now.
Replaced tablet door magnet catch
Cleared dust from thermal sensor
Suggest floor inserts for cracked floor,contact Clearlight
Attachments: https://bizinstall.com.au/wp-content/uploads/formidable/10/16880759869411081973627608455856-150×150.jpg, https://bizinstall.com.au/wp-content/uploads/formidable/10/16880760380711231950528311808979-150×150.jpg, https://bizinstall.com.au/wp-content/uploads/formidable/10/1688076776752609462079886084511-150×150.jpg, https://bizinstall.com.au/wp-content/uploads/formidable/10/16880772083772150101075697095048-150×150.jpg, https://bizinstall.com.au/wp-content/uploads/formidable/10/16880787424877279946274633192903-150×150.jpg, https://bizinstall.com.au/wp-content/uploads/formidable/10/16880787528773782513758639967347-150×150.jpg